国产在线精品亚洲第一区

    <object id="xm9bc"></object>
    <tr id="xm9bc"></tr>
  • <tr id="xm9bc"></tr>

  • <object id="xm9bc"></object>
    Home
    Products
    About Us
    Factory Tour
    Quality Control
    Contact Us
    Request A Quote
    News
    Home ProductsMechanical Control Valve

    Fleck Control Valves Water Softening Equipment For Calcium Magnesium Exchange

    China China Concrete Autoclave Online Market certification
    China China Concrete Autoclave Online Market certification
    The company considerate after-sales service ,And try their best to meet the requirement of customers. We will be a long-term cooperation.

    —— Albert

    Cooperation is very satisfactory and the Company of the past few years, we are very willing to continue long-term cooperation.

    —— Dean

    I want to say that your products very good. Thank you for all your suggestion, also good after sales service.

    —— Mr Abílio Cipriano

    I'm Online Chat Now

    Fleck Control Valves Water Softening Equipment For Calcium Magnesium Exchange

    Fleck Control Valves Water Softening Equipment For Calcium Magnesium Exchange
    Fleck Control Valves Water Softening Equipment For Calcium Magnesium Exchange Fleck Control Valves Water Softening Equipment For Calcium Magnesium Exchange

    Large Image :  Fleck Control Valves Water Softening Equipment For Calcium Magnesium Exchange

    Product Details:

    Place of Origin: China
    Brand Name: YLD
    Certification: CE/ SGS/ISO
    Model Number: YL-II-3

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 unit
    Price: negotiation
    Packaging Details: With plywood case for outer packing
    Delivery Time: 10 working days after received your payment
    Payment Terms: T/T or western Union or L/C
    Supply Ability: 500 units per month
    Detailed Product Description
    Product Name: Water Softening Equipment Application: Hard Water Softening
    Flow Rate: 3m3/Hr Material: SUS 304/GRP
    Tank Size: 3500*1400mm Brine Tank: 130L
    Working Temperature: 5-50℃ Power Supply: According To Customers Require
    Inlet Water Pressure: 0.2~0.4Mpa Resin: 160KG
    High Light:

    shower head water softener

    ,

    resin water softener

    Fleck Control Valves Water Softening Equipment For Calcium Magnesium Exchange

     

     

    Introduction:

     

    Metered water softeners or demand water softeners, count down the set capacity of the softener in 

    gallons. A softener with a meter initiated control will only regenerate when required as determined by 

    the volume of water softened. 

    With a mechanical metered water softener system, homeowners can save both water and salt by 

    regenerating the on demand softener only when required as compared with time clock initiated controls.

     

    Hard water is not considered unhealthy, but hard water problems end up costing you money through 

    increased soap usage, build up of calcium scale in your pipes, and shortening the life of your appliances.

     

    The ion exchange water softener is one of the most common tools of water treatment. Its function is to

     remove scale-forming calcium and magnesium ions from hard water. In many cases soluble iron (ferrous) can also be

     removed with softeners. A standard water softener has four major components: a resin tank, resin, a 

    brine tank and a valve or controller.

     

    The softener resin tank contains the treated ion exchange resin - small beads of polystyrene. The resin

     beads initially adsorb sodium ions during regeneration. The resin has a greater affinity for multi-valent ions such as calcium and magnesium than it does for sodium. Thus, when the hard water 

    containing the Calcium and Magnesium Ions is passed through the resin bed, the calcium and magnesium

     ions adhere to the resin, releasing the sodium ions until equilibrium is reached. The water softener has 

    exchanged its sodium ions for the calcium and magnesium ions in the water.

    Regeneration is achieved by passing a NaCl solution through the resin, exchanging the hardness ions for

     sodium ions. The resin’s affinity for the hardness ions is overcome by using a highly concentrated solution

     of brine. The regeneration process can be repeated indefinitely without damaging the resin.

     

    Specifications:

     

    Category

    Model

    Recommended water yield

    (M³/h)

    Tank size

    Diameter *Height(mm)

    Salt box

    (L)

    Amount of resin(KG)

     

     

     

     

     

     

     

    Single-valve and single-tank

    YL-I-0.5

    0.5

    200×900

    25

    20

    YL-I-1

    1

    250×1400

    60

    40

    YL-I-2

    2

    300×1400

    200

    60

    YL-I-3

    3

    350×1400

    100

    80

    YL-I-4

    4

    400×1650

    200

    120

    YL-I-5

    5

    500×1750

    300

    180

    YL-I-6

    6

    300×1900

    350

    240

    YL-I-10

    8-10

    750×1900

    500

    360

    YL-I-18

    42-18

    900×1900

    800

    520

    YL-I-25

    18-25

    1000×2200

    1000

    720

    YL-I-35

    25-30

    1200×2400

    1500

    1000

    YL-I-50

    35-50

    1500×2500

    2000

    6400

    Dual-valve and dual-tank (simultaneous operation and respective regeneration)

    YL-II-36

    24-36

    900×1900

    800

    1040

    YL-II-50

    36-50

    1000×2200

    1000

    1440

    YL-II-70

    50-70

    1200×2400

    1500

    2000

    YL-II-100

    70-100

    1500×2500

    2000

    3200

     

     

     

     

     

    Dual-valve and dual-tank(One for use and the other for standby)

    YL-II-1

    1

    250×1400

    60

    80

    YL-II-2

    2

    300×1400

    100

    120

    YL-II-3

    3

    350×1400

    100

    160

    YL-II-4

    4

    400×1650

    200

    240

    YL-II-5

    5

    500×1750

    300

    360

    YL-II-6

    6

    600×1900

    350

    480

    YL-II-10

    8-10

    750×1900

    500

    720

    YL-II-18

    12-18

    900×1900

    800

    1040

    YL-II-25

    18-25

    1000×2200

    1000

    1440

    YL-II-35

    25-35

    1200×2400

    1500

    2000

    YL-II-50

    35-50

    1500×2500

    2000

    3200

     

     

     

    Working principle

     

    To absorb the calcium and magnesium ions in the water with resin. As the hardness of the water is mainly formed and expressed by calcium and magnesium, the cation exchange resin (water softener)is generally used to replaceCa2 + and Mg2in the water The resin efficiency to removeca2 + and Mg2+ gradually reduces as ca2 + and Mg2 + in the resin increase. When the resin absorbs a certain amount of calcium and magnesium ions, it is necessary to be regenerated. In the regeneration process, the resin bed is flushed by saline in the salt box and hardness ions on the resin are replaced and discharged with recycled waste fluid, the resin’s function of softening exchange is recovered. The principle of sodium ion exchanging softening treatment is to use sodium cation exchange resin to exchange the hardness ingredients, Ca2 + and Mg2 +, in the raw water with Na + in the resin, absorbing Ca2 + and Mg2 + in the water, so that water gets softened.

    Fleck Control Valves Water Softening Equipment For Calcium Magnesium Exchange 0

     

    Applications:

     

    System automatic water softener widely used in steam bioler,heating bioler,exchanger,air conditioner,

     and other systems water softener,also used in hotel,restruant,office, and other life water treatment and

     food,drinking,wine,washing,textile,chemical,medicine and other industrial softener water treatment.

     

     

     

    Technical parameters

     

    Hardness of

    raw water

    ≤8mmol/L

    Power supply

    220V/50HZ

    Hardness of effluent

    ≤0.03mmol/L

    Control mode

    flow rate type, time type

    Inlet water pressure

    0.2~0.4Mpa

    Resin

    001×7 strong acidic cation-exchange

    Free chlorine

    ≤0.3mg/L

    Working ambient temperature

    5-50℃

    Suspended solid

    <0.5mg/L

    System water temperature

    5-45℃

    Iron content

    <0.3mg/L

    Relative humidity

    ≤95%(25℃)

     

     

    Fleck Control Valves Water Softening Equipment For Calcium Magnesium Exchange 1

     

     

     

     

     

    Contact Details
    China Concrete Autoclave Online Market

    Contact Person: tt

    Send your inquiry directly to us (0 / 3000)

    国产在线精品亚洲第一区
    <object id="xm9bc"></object>
    <tr id="xm9bc"></tr>
  • <tr id="xm9bc"></tr>

  • <object id="xm9bc"></object>